重量差二次称重法电梯平衡系数测试原理

日期: 2010-2-20 20:53:11 浏览: 7 来源: 学海网收集整理 作者: 辽宁省抚顺市特种设备监督检验所 杨鹏

摘要 本文指出了动态电流(电压/功率/转速)法测试电梯平衡系数的方法存在的缺陷。根据平衡系数定义公式提出了静态重量差二次称重法直接测试电梯平衡系数原理;论述了如何消除摩擦阻力对重量差测试结果的影响和利用测得的重量差求解传动系统机械效率,从而掌握电梯耗能情况。
   关键词:静态重量差 二次称重 直接测试 电梯平衡系数 原理
   The static state weighs difference is two weighing of method direct test elevator equilibrium coefficient principle with applied
   FUSHUN Supervisor inspection institute for special equipment
   YANG PENG (113006)
   Abstract : This text discuss that there are some problems in the current(voltage or power or rotational speed) testing to the balance coefficient of method. According to the definition formula of the balance coefficient, a new testing principle have been put forward that static state weighs difference is two weighing of method direct test elevator equilibrium coefficient principle ,Discussing How remove friction drag to weight difference test result of effect and make use of measured weight difference find drive system machinery efficiency thus grasp elevator consumes energy condition.
   Key words : static state weighs difference ; two weighing, direct test; Elevator balance coefficient; principle.
   前言
   电梯平衡系数是电梯验收检验及电梯装修后需要检验的重要参数之一,是关系到电梯安全、经济运行的一项重要参数。现行国家标准推荐、《检规》规定的检验方法是:“轿厢分别承载0、25%、50%、75%、100%的额定载荷,进行沿全程直驶运行试验,分别记录轿厢上、下行至与对重同一水平面时的电流、电压或速度值。对于交流电动机通过电流测量并结合速度测量,做电流-载荷曲线或速度-载荷曲线,以上、下运行曲线的交点来确定平衡系数。电流应用钳型电流表从交流电动机输入端测量。对于直流电动机通过电流测量并结合电压测量,做电流-载荷曲线或电压-载荷曲线,确定平衡系数。”该方法是一种间接测试方法,其原理正确,但存在诸多不足之处:由于动态测试是瞬间读数,随机误差和测试数据复现性差,所以测试精度低、综合积累误差大、置信水平底,而且测试工作量大,费时、耗能、检验效率低。本文根据电梯平衡系数的定义,提出了《静态重量差二次称重法直接测试电梯平衡系数原理》和方法,可提高检验效率和测试精度并节约能源,袮补了动态测试方法的不足。
   ......